Wires/Cables & Accessories
P.V.C. Insulated & Sheathed 3 Core Flat Cables.
Conductor
|
Nominal Area Sq. mm
|
1.00
|
1.50
|
2.50
|
4.00
|
6.00
|
10.00
|
16.00
|
25.00
|
35.00
|
50.00
|
No. of Wires and Wire Diameter (mm)
|
32/0.20
|
22/0.30
|
36/0.30
|
57/0.30
|
85/0.30
|
141/0.30
|
226/0.30
|
354/0.30
|
495/0.30
|
708/0.30
|
Insulation
|
Radial thickness mm (nominal)
|
0.60
|
0.60
|
0.70
|
0.80
|
0.80
|
1.00
|
1.00
|
1.20
|
1.20
|
1.40
|
Core Diameter mm (nominal)
|
2.60
|
2.90
|
3.55
|
4.55
|
5.20
|
6.65
|
7.90
|
9.75
|
10.90
|
12.65
|
Sheath
|
Thickness of Sheath mm (nominal)
|
0.90
|
0.90
|
1.00
|
1.10
|
1.10
|
1.20
|
1.30
|
1.50
|
1.60
|
1.70
|
Overall Dimension (mm)
(Max.)
|
10.50
X
5.00
|
11.50
X
5.40
|
14.00
X
6.40
|
16.50
X
7.20
|
18.00
X
8.00
|
22.50
X
9.60
|
26.50
X
11.00
|
32.50
X
13.50
|
36.00
X
15.00
|
41.50
X
17.00
|
Mechanical Field
|
Conductor elongation at break
|
Min. 9% up to 0.21 mm and Min. 13.5% above 0.21 to 0.41 mm wire Diameters
|
Insulation-Tensile Strength
|
12.5 N/mm (Min.)
|
Insulation-elongation at break
|
150% (Min.)
|
| Sheath-Tensile strength |
12.5 N/mm2 (Min)
|
Sheath-elongation at break
|
150% (Min.)
|
Electrical
|
Conductor Resistance at 20degC ohms/km (Max.)
|
19.50
|
12.10
|
7.41
|
4.95
|
3.30
|
1.91
|
1.21
|
0.780
|
0.554
|
0.386
|
Current carrying capacity at an ambient temperature at 40°C (Amp.)
|
11
|
14
|
18
|
26
|
31
|
42
|
52
|
72
|
90
|
115
|
Max. Conductor Temperature
|
70°C
|
Effect of Humidity
|
Nil
|
|
Approximate Weight (kg/km)
|
82.500
|
92.500
|
150.000
|
239.500
|
32.000
|
507.500
|
746.500
|
1143.500
|
1495.000
|
2062.000
|
|